1. Lascar Electronics EL-USB-3 USB Voltage Data Logger, Process, 32,000+ readings, 1 year battery life
Feature
SelectableConfiguration Software
32, 510 reading memory
Description
This data logger measures and stores up to 32, 510 voltage readings over a 0-30V D.Sc. measurement range. The user can easily set up the logging rate and start time, and download the stored data by plugging the module straight into a PCs USB port and running the purpose designed software under Windows 2000, XP, Vista & 7. The data can then be graphed, printed and exported to other applications.
2. HOBO by Onset UX120-006M Analog Data Logger
Feature
HOBO UX120 4-Channel Analog LoggerTwice the accuracy over previous models with 16-bit resolution
Flexible support for a wide range of external sensors
LCD confirms logger operation and displays near real-time measurement data
Provides minimum, maximum, average and standard deviation logging options
Description
The HOBO UX120-006M Analog Data Logger is a high-performance, LCD display data logger for building performance monitoring applications.As Onset's highest-accuracy data logger, it provides twice the accuracy of previous models, a deployment-friendly LCD, and flexible support up to four external sensors for measuring temperature, current, CO2, voltage, and more.The data logger is ideal for energy audits, building commissioning studies, equipment scheduling, and more.IMPORTANT: HOBO data loggers require HOBOware software (USB interface cable included w/CD purchase).3. Extech DL160 Dual Input True RMS AC Voltage/Current Datalogger
Feature
Datalog up to 256,000 readings with user programmable sample rateSimultaneously measure two AC voltage inputs or two AC current inputs or one AC voltage and one AC current input
Readings can be downloaded to your PC via the USB interface and analyzed using the included software or exported to a spreadsheet
LCD indicates time/date, current readings and Min/Max
Auto Power off and battery check
Description
Dual Input True RMS AC Voltage/Current Datalogger
Capable of datalogging 2 channels simultaneouslyup to 256,000 readings of TRMS AC Voltage (600 volts) or Current (200 amp) or one AC Voltage and one AC Current input with a user programmable sample rate from 1 second to 24 hours.
Additional Features
LCD displays time/date, current reading, and min/max. Readings can be downloaded to your PC via the USB interface. Normal, peak, and capture (user specified trigger level) recording modes.
Includes
Comes with two current clamps, two sets of test leads, two sets of alligator clips, software, USB cable, universal AC adapter, and four AAA and two CR2032 batteries.
More Extech Instruments to Choose From
View larger
True RMS AC Voltage/Current Datalogger
Capable of datalogging up to 100,000 readings of TRMS AC Voltage (600 volts) or Current (200 amp) with a user programmable sample rate from 1 second to 24 hours. LCD displays time/date, current reading, min/max, and if the user settable high/low alarms have been exceeded. Readings can be downloaded to your PC via the USB interface. Normal, peak, and capture (user specified trigger level) recording modes. Complete with current clamp, test leads, alligator clips, software, USB cable, universal AC adapter, and four AAA batteries.
4. AEMC L261 Single-Channel AC Voltage Simple Logger II, Resistance, 600V AC/DC Voltage
Feature
One-channel, programmable data logger for voltage measuring, monitoring, and troubleshootingTrue RMS (root mean square) voltage recording up to 600V AC/DC
Five LED indicators display logger status
Compact and lightweight (6.4 oz. with battery)
Meets EN safety standard 61010-1; 300V Category IV; 600V Category III; Pollution Degree 2
Description
The AEMC Simple Logger II Model L261 is a lightweight (6.4 oz. with battery), one-channel, programmable data logger for voltage measuring, monitoring, and troubleshooting, with a safety rating of EN 61010-1; 300V Category IV; 600V Category III. It offers true RMS (root mean square) voltage recording up to 600V AC/DC, and the five LED indicators display logger status. The four user-selectable storage modes are Start/Stop, FIFO (First In First Out), Extended Recording Mode (XRM), and Alarm. Programmable storage rates range from eight per second to one per day. The logger can store up to 240,000 measurements and comes with DataView software for data storage, real-time waveform display, analysis, and report generation. The recorded data are stored in nonvolatile memory and remain even if the battery is low or removed. Applications include long-term supply monitoring, recording voltage surges and sags, locating intermittent voltage problems, monitoring voltage harmonics, or machine monitoring.
Specifications
Input connection | Two recessed 4 mm safety banana jacks |
Measurement range | 0 to 600V AC/DC |
Accuracy | 0 to 5V: unspecified; 5 to 50V: + or - (0.5% of reading + 1V); 50 to 600V: + or - (0.5% of reading + 0.5V) |
Recording length | 15 minutes to 8 weeks |
Sample rate | 64 samples per cycle |
Storage rate | Programmable from 125ms to 1 per day |
Memory | 240,000 measurements (512KB) |
Power source | Two 1.5V AA alkaline batteries (included) |
Battery life | 100 hours to more than 45 days (depending on sample rate and recording length) |
Safety | Safety rating: EN 61010-1, 300V Category IV, 600V Category III, Pollution Degree 2; Vibration: IEC 68-2-6 (1.5mm, 10 to 55Hz); Shock: IEC 68-2-27 (30G); Drop: IEC 68-2-32 (1m) |
Dimensions | 4.94 x 2.75 x 1.28 inches (125 x 70 x 32 mm) H x W x D |
H is height, the vertical distance from lowest to highest point; W is width, the horizontal distance from left to right; D is depth, the horizontal distance from front to back.
Voltage testers detect electrical current in cables, cords, circuit breakers, switches, wiring, and other components of electrical systems. They can test for live circuits, proper grounding, adequate voltage, and flowing current. They might be used by homeowners to test electrical outlets or by linemen to test power lines. Available in a variety of styles and levels of sophistication, some models simply indicate the presence of electrical current, while others record or display the level of voltage conducted. Some have additional capability such as the ability to perform continuity tests.
AEMC Instruments manufactures electrical testing and measurement instruments, including clamp meters, power quality analyzers, ground resistance testers, and data loggers. The company, founded in 1893, is headquartered in Foxborough, MA.
What's in the Box?
- Simple Logger II, L261
- (2) Color-coded 5 ft. voltage leads
- Color-coded alligator clips (red/black)
- USB Type A to 5-pin Mini-B cable
- DataView software
- (2) 1.5V AA alkaline batteries
5. Supco LCV LOGiT Current and Voltage Data Logger, 3" Length x 2-1/2" Width x 1-3/32" Height
Feature
External current probe and voltage measurementsOver/under alarms for current and voltage visual alarm indication
Simultaneous single phase current and voltage monitoring verification of power conditions, compressor and fan run cycles and use three LCV's for three phase applications
Single point offset calibration available through software
Measures 3" length by 2-1/2" width by 1-3/32" height; 1 year warranty
Description
The LCV data logger is a precision instrument for recording AC current and AC voltage. AC current is sampled using the supplied clamp probe. The logger can store up to 21,500 and up to 10,750 data points, when it is setup to record either AC current or AC voltage (but not both). Each logger is factory calibrated. This means that the clamp probes are not interchangeable. Sample point capacity: 10750 and 21500 points for current and voltage. Sample rate: 1 second to 18 hour. Alarms: over and under alarms for current and voltage visual alarm indication. Current range: 0 to300 Amps AC. Current accuracy: +/- 5 percent. Current resolution: 0.1 Amp AC. Voltage range: 0 to 500 volts AC. Voltage accuracy: +/- 1 V AC. Voltage resolution: 0.1 VAC. Time accuracy: +/- 100ppm at 75 degree F. Operating temperature range: 32 to 140 degree F (0 to 60 degree C) using alkaline battery, -40 to 150 degree F (-40 to 65 degree C) using lithium battery. Humidity: 0 to 95 percent, Non-condensing. Storage temperature: -40 degree F OE 170 degree F (-40 degree C OE 77 degree C). Calibration: single point offset calibration available through software, current and voltage are factory calibrated. Power source: 9V alkaline or lithium battery. Battery life (average use): 20 months using alkaline battery, 40 months using lithium battery. Measures: 3" length by 2-1/2" width by 1-3/32" height. Weight: 2.5 oz (71g). 1 Year warranty.6. OWON OW18B Digital Multimeter Bluetooth Data Logger NCV Supported mobile app true RMS Flashlight Temperature test With K-type Thermocouple
Feature
Large display with flashlight,widely supported on Android, iOS and WindowsNCV non-contact voltage sense--While getting the non-contact voltage sensor close to conductor, the instrument will beeps and flash with the frequency according to AC voltage strength
Multifunctional,can measure AC/DC voltage, AC/DC current, resistance, diode, capacitance,frequency, duty ratio,temperature,continuity,NCV
This Digital Multimeter support bluetooth wireless transmission
Automatic recorder trend chart, NCV true RMS, Bluetooth 4.0
Description
Features:Brand:OWON
Model: OW18B
Color: blue&gray
Display:5999 counts
Frequency Response:(20 - 1000) Hz
Sample rate:3 times/second
Battery: 9V battery(not included)
Bluetooth Module:Yes
NCV:Yes
True RMS:Yes
Diode Test:Yes
Auto Power-off:Yes
On-off Warning:Yes
Low-battery Indicator:Yes
Data Hold:Yes
Relative Measurement:Yes
Flashlight:Yes
Auto-scale:Yes
LCD Backlight:Yes
Automatic-manual Range Selection:Yes
Specification:
DC voltage range: 600.0mV/6.000V/60.00V/600.0V,0.1mV,(0.5%+2);1000V,1V,(0.8%+2)
AC voltage range: 600.0mV/6.000V/60.00V/600.0V,0.1mV,(0.8%+3);750V,1V,(1%+3)
DC current: 60.00uA/600.0A,0.01A,(0.8%+2dig);60.00mA/600.0mA,0.01mA (0.8%+2dig);10.00A,0.01A,(1.2%+3dig)
AC current: 60.00uA/600.0A,0.01A,(1%+3dig);60.00mA/600.0mA,0.01mA,(1%+3dig);10.00A,0.01A,(1.5%+3dig)
Resistance:600.0/6.000k/60.00k/600.0k/6.000M,0.1,(0.8%+2dig);60.00M,0.01 M,(2%+3dig)
Frequency range:9.999Hz/99,99Hz/999.9Hz/9.999kHz;99.99kHz/99.9kHz/9.999MHz,0.001Hz,(0.8%+2dig)
Capacitance range: 60.00nF/600.0nF/6.000F/60.00F,01nF,(2.5%+3dig);600.0F/6.000mF/60.00mF,0.1F,(3%+5dig)
Duty ratio range:0.1%~99.9%(typical value: Vrms=1V,f=1kHz),0.1%,(1.2%+3dig);0.1%~99.9%(1kHz),0.1%,(2.5%+3dig)
Temperature Range: - 50 ~ +400 ,1, (2.5%+3dig);-58 ~ +752 ,1 ,(4.5%+5dig)
Input Protection:Yes
Input impedance:10M
Safety Compliance: 600V CAT, 1000V CAT
Dimension (WHD):196 x 88.5 x56 (mm)
Weight (without package): 0.30 kg
Package Included:
1 x Digital Multimeter
1 x Pair of test leads
2 x Alligator Clip
1 x Thermocouple
1 x User Manual
7. NEULOG NUL201 Voltage Logger Sensor, 15 bit ADC Resolution, 1 Percent Accuracy
Feature
Logger sensor for measuring voltageCan be used with Van de Graaff generators, fuel cells, batteries, and parallel and series circuits for further study
Attachable to NUL 202 current logger sensor to study current dependence on voltage in various electric circuits (sold separately)
"Required accessories-To use sensors you will need either: a USB Module (USB 200) to connect via USB cable to PC or Mac, or a Wi-Fi Module (WIFI201) and battery (BAT200) to connect to any Wi-Fi enabled device (Smart Phone, Tablet, Computer)"
Experiment duration of 50.0 milliseconds to 31.0 days for versatile use, and 15.0-bit analog-to-digital converter (ADC) resolution for reading range of values
Description
NeuLog logger sensor measures voltages, and can be used with Van de Graaff generators, fuel cells, batteries, and parallel and series circuits for further study. The logger sensor has power and ground wires with 4.0mm plugs to connect to electric circuits, and is attachable to the NUL 202 current logger sensor to study current dependence on voltage in various electric circuits (sensor sold separately). The logger sensor has an experiment duration of 50.0 milliseconds to 31.0 days, and 15.0-bit analog-to-digital converter (ADC) resolution for reading a range of values. The logger sensor measures low-voltage AC and DC circuits and, with a step-down transformer, can measure the AC voltage of the main supply and check its frequency up to 50.0/60.0Hz. (Transformer sold separately; the sensors input is limited to 60.0Hz and +/-20.0V maximum.) The voltage logger sensor can be used for physics, electronics, chemistry, and biology experiments, and is suitable for grade 3 and higher, or ages 10 to 21.
The logger sensor consists of a data logger, flash memory, and a sensor for fully self-contained data gathering, and is plug-and-play for immediate readings as soon as it is connected. The logger sensor sends data in digital format to a PC, Mac, tablet, smart phone, or other viewer device, and provides multiple connection options, including USB and wireless. The logger sensors browser-based software adjusts ranges and gains, and provides applications for presenting data, including online and offline modes, tables, graphs, data analysis, double-axis set up, statistic operations, and mathematical operations. The logger sensor is encased in durable plastic, and has an LED indicator to track experiment status, with push buttons for calibration and start/stop experiments in offline mode for ease of operation. To take an assortment of readings during a single experiment, the logger sensor can be attached to another sensor; one to 10 logger sensors can be used per experiment (sensors sold individually). For efficiency, the logger sensor can store up to five experiments in flash memory, and saved experiments can be uploaded to a PC or Mac at any time. Additional accessories, such as USB, Wi-Fi, or battery modules, are required for operation depending on the device (PC, tablet, viewer, and so on) used to receive readings from the sensor. (Accessories and devices sold separately.) The logger sensor includes a guide with instructions for use and care, and measures 6.5 x 7.0 x 1.5cm (L x W x H). (L is length, the horizontal distance from left to right; W is width, the horizontal distance from front to back; H is height, the vertical distance from the lowest to highest point.)
Logger sensors are electronic devices used to record a variety of energy and environmental measurements, such as temperature, humidity, voltage, and soil moisture, at set intervals over a period of time in scientific classroom and field settings.
Specifications
Range and operation modes +/- 20.0V
ADC resolution 15.0 bit
Accuracy 1.0%
Resolution 0.01V
Maximum sample rate (S/sec) 100.0 long duration
3,000.0 short duration
Science education products incorporate applied math and science principles into classroom and homeschool-based projects. Teachers in pre-K, elementary, and secondary classrooms use science education kits and products alongside science, technology, engineering, and math (STEM) curriculum to demonstrate STEM concepts and real-world applications through hands-on activities. Science education projects include a broad range of activities, such as practical experiments in engineering, aeronautics, robotics, energy, chemistry, physics, biology, and geology.
NeuLog brand products, manufactured by EISCO Scientific and Science Educational Systems (SES), include logger sensors, software, and accessories for energy and environmental data acquisition and measurement. EISCO Scientific was founded in 1968, and is headquartered in Rochester, NY; SES was founded in 1983, and is headquartered in Israel. Both companies meet International Organization of Standardization (ISO) standard 9001.
Whats in the Box?
Voltage logger sensor
Power and ground wires
4.0mm plugs
Guide
8. TRC AECM20020-3-012 Electra Check Digital Monitor for All AC Power Sources, Black with White Face
Feature
Accurate testing and monitoring of all AC power source typesRMS voltage and frequency meter
One button operation
LCD Display with LED backlight
Advanced Microelectronics
9. Lascar EL-USB-5 USB Data Logger, Counter, Event and State
Feature
Accepts input voltage up to 24VVolt free contact option
Rising and falling edge triggering
Description
This standalone data logger can record events (detecting an input and storing the time and date of occurrence), record state changes (similar to an event but also recording when the input reverts back to normal) and count events (count the number of events that happen in a time period, without any individual event time or date information). Up to 32, 510 events or 32, 510 state changes can be recorded.
10. Fluke VR1710 Voltage Quality Recorder
Feature
Continuous recording of all values with No gaps - save testing time by getting the whole picture with one instrument that records both events and VoltageClear graphical summary of data and quick overview of Key power quality parameters
The Vr1710 Includes Plug-In Fluke Vr1710, USB cable
Fast and easy recording of voltage trends, dropouts, and power quality - Easily pinpoint the root cause of single phase voltage problems
Extremely easy to use - Plug directly into the mains power socket and capture data
Continuous recording of all values with no gaps - Save testing time by getting the whole picture with one instrument that records both events and voltage
Clear graphical summary of data and quick overview of key power quality parameters
The VR1710 includes plug-in Fluke VR1710, USB cable